  • Wall mount configuration 9” W x 6.5” H x 7.25” D
  • Powerful 32-bit processor & 24 –bit A/D converter
  • Language neutral color LCD 12 line 480 x 272 operator display
  • Bar Graph display  (pressure, loss, or flow)-English, Chinese, Korean, Spanish
  • Individual LED Pass/Fail/In-test test status indicators
  • Expanded instrument control through EtherNet/IP™ Communication
  • Modular pneumatic and control packages
  • Single test channel
  • Auto Calibration includes mass flow leak standard certified for pressure and flow
  • Transducer zero and span are automatically reset during auto calibration
  • “Performance factor” calibration feedback ensures accurate results
  • Manual edit of Calibration Program permitted
  • Self Test isolates the test instrument pneumatics to verify a “no leak” condition
  • Features ensure accurate results and easy operator setup and troubleshooting
  • Firmware validation document included

 

Standard pressure transducer, valve manifolds, and regulator ranges: -14.5, 2, 30, 100, 200, or electronic regulator (PSIG)

  • Optional High cV flow valves and manifold available up to 100 psig range allows 5 times faster fill and exhaust to reduce cycle times on large parts
  • Absolute pressure transducer
  • Two (2) point pressure calibration
  • Data resolution 0.00001 psi/ and scc/m.
  • Optional electronic regulator available with multi-point calibration
  • Pressure:PSIG, PSIV, inH2O, cmH2O, mmH2O, kg/cm2, ATM, inHg, cmHg, mmHg, kPa, Pa, MPa, Bar, mBar, Torr
  • Flow:Sccm, sccs, scch, slpm, slps, slph, scfm, scfs, scfh
  • Time:Sec, msec, min
  • Units of measure can be instrument global or per test program

 

  • Expanded control through EtherNet/IP™ Communication
  • 6 inputs/3 outputs - 1 programmable tooling motion - no feedback
  • Tooling I/O is  internally connected
  • I/O 24 VDC – optional I/O cable “Cable,CTS, P56-540”
  • Up to 5000 LIFO part results including Date / Time / Test Results
  • SPC data tracking for part traceability
  • 88-264 VAC, 47-63 Hz or optional 22-26 VDC
  • RS232(1)
  • Telnet(1)
  • USB storage device for firmware upload only (FAT32, USB1.0,1.1,2.0)
  • ¼” Colder fitting for test line attachment

 

 

 

Testing Technologies

Single Test Configurable for Pressure or Vacuum Decay Test Requirements

  • Pressure/Vacuum decay-pressure change
  • Pressure/Vacuum decay-with certified mass flow leak standard
  • Pressure/Vacuum decay-pressure change/time
  • Occlusion test (vacuum or pressure test)
  • Storage for 32 pre-programmed test sequences
  • Test Program can be selected through keypad, or binary input pulse
  • Test results evaluation is fixed (Fail/Pass/Fail)
  • Test result output format is configurable

Selectable Test Parameters

  • Quick Test
  • Test Pressure Level Compensation
  • Adjustable Environmental Drift Correction per test program